Characteristics
Symbol
Unit
Condition
LP3
LP3A
LP4
LP3S
LP8
Initial permeability
µi
2300±25%
2400±25%
2000±25%
2500±25%
3000±25%
Relative loss factor
tanδ/µi
100kHz
< 4×10-6
< 3×10-6
< 5×10-6
< 3×10-6
< 4×10-6
Saturation flux density
Bs
mT
25°C
500
510
530
530
500
100°C
390
390
450
420
380
Remanence
Br
mT
130
110
150
180
110
Coercivity
Hc
A/m
13
10
13
13
11
Power loss (f=100kHz,B=100mT)
Pcv
kW/m3
25°C
80°C
90
70
100°C
70
50
Power loss (f=100kHz,B=200mT)
Pcv
kW/m3
25°C
650
600
700
600
550
80°C
450
360
500
300
320
100°C
410
320
450
250
380
120°C
400
360
Curie temperature
Tc
°C
≥ 215
≥ 215
≥ 270
≥ 230
≥ 215
Resistivity
ρ
Ω∙m
5
5
5
4
6
Density
δ
g/cm3
4,8
4,8
4,9
4,9
4,8
Characteristics
Symbol
Unit
Condition
LP9
LP90
LP3F
LP5
Initial permeability
µi
3300±25%
2000±25%
2000±25%
1400±25%
Relative loss factor
tanδ/µi
100kHz
< 4×10-6
< 5×10-6
< 5×10-6
< 5×10-6
Saturation flux density
Bs
mT
25°C
520
530
470
460
100°C
410
450
360
350
Remanence
Br
mT
90
170
110
140
Coercivity
Hc
A/m
9
13
14
20
Power loss (f=100kHz,B=100mT)
Pcv
kW/m3
25°C
80°C
100°C
150*
80**
Power loss (f=100kHz,B=200mT)
Pcv
kW/m3
25°C
350
680
80°C
300
360
100°C
320
320
120°C
370
450
Curie temperature
Tc
°C
≥ 215
≥ 270
≥ 200
≥ 250
Resistivity
ρ
Ω∙m
6
4
5
8
Density
δ
g/cm3
4,9
4,9
4,75
4,7

Примітки:

Значення параметрів отримані на кільцевому осерді К25х15х10.

* – при f=400kHz, B=50mT

** – при f=500kHz, B=50mT

Адреса:
Украина, Киевская обл., г. Белая Церковь, ул. Фастовская, 22
Телефон:
+38(067)-245-37-43
Пошта:
abatnat@gmail.com